Vortech 2003-2004 Chevrolet SS User Manual

Page 52

Advertising
background image

34

P/N: 4GL020-015

©2008 Vortech Engineering, LLC

All Rights Reserved, Intl. Copr. Secured

08OCT08 GM Trk/H2(4GL..015v5.0)

19. WATER PUMP WIRING

A.1 Escalade/Denali/SS: Mount the supplied

water pump relay on the fire wall located to

the right of the FMU bracket. (See Fig. 19-a.)

A.2 H2 Hummer: Mount the supplied water pump

relay on the lower plastic area of the power

distribution block next to the fuel pump relay.

(See Fig. 11-f.)

B. Connect the red 12-gauge wire from terminal

#30 to the supplied fuse holder using the sup-

plied butt connector. Install a ring terminal on

the other end of the fuse holder. (See Fig.

19-b.)

C. Feed the yellow wire from relay terminal #85

to the fuse box (electrical center) on the driv-

er’s side of the engine bay. Route the wire to

the yellow wire from the fuel pump relay. Tap

into the line using the supplied “T” splice con-

nector. (See Fig. 19-b.) If the vehicle does not

require an inline fuel pump, route the wires

directly to the fuel pump relay. (See Fig.

19-c.)

Fig. 19-a

Fig. 19-b

TAP INTO FUEL

PUMP WIRE

FUSE BOX

POWER SUPPLY

Fig. 19-c

NOTE: Vehicles not using supplement fuel pump will tap into

the stock fuel pump relay using the supplied fuse tap.

(See Fig. 19-c.)

D. Run the black wire from terminal #86 on the

fuel pump relay to ground.

E.1 Escalade/Denali/SS: With the long red

12-gauge wire connected to the water pump

relay terminal #87, route the free end down

along the fenderwell and under the base of

the radiator over to the positive (blue/green)

wire on the water pump. Secure as necessary

to avoid heat and sharp edges.

E.2 H2 Hummer: With the long red 12-gauge

wire connected to the water pump relay ter-

minal #87, route the free end down the fend-

erwell to the positive (blue/green) wire on the

water pump. Secure as necessary to avoid

heat and sharp edges.

F. Run the negative (brown) wire from the water

pump to a clean ground.

G. With the key on, make sure the charge cooler

water pump is operating and that water is

flowing through the surge tank. Fill the surge

tank if necessary. If the water is not flowing,

remove the charge cooler supply hose and

lower until water flows out of the hose. If nec-

essary, provide light suction to the hose to

help prime the pump. Verify water flow. Do

not let the pump run for extended periods (30

seconds or more) without water flow. Fill the

charge cooler tank until the level stabilizes.

RED WIRE FROM VORTECH SUPPLIED

RELAY TERMINAL #30 ATTACHES HERE

YELLOW WIRE FROM VORTECH SUPPLIED

RELAY TERMINAL #85 ATTACHES HERE

Advertising
This manual is related to the following products: