Wiring schematics cont, Legend, Nskw installation manual – WaterFurnace Envision Hydronic User Manual

Page 21: Johnson fx-10

Advertising
background image

21

NSKW INSTALLATION MANUAL

Wiring Schematics cont.

Reversible - 380-420/50/3 cont.

Blk/Wht

Yellow

T

T

T

T

ELT

LLT

LST

LFD

T

SFP

T

EST

Brown (41)

Brown (42)

White (43)

Wht/Blu (44)

Black (45)

Blk/Red (46)

Gray (47)

Gray/Wht (48)

Blue (49)

Blue/Wht (50)

Orange (51)
Org/Wht (52)

Black

Blk/Wht (69)

Yellow (68)

97P799-12 1/19/12

Johnson

FX-10

5VDC

AI3

23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38

+

-

AI5

-
+

AI4

-
+

AI6

AI2

AI1

5VDC

5VDC

LED

-

-

-

+

+

+

24

VAC

24

VAC Com

GROUND

39

40
41

PWM2
PWM2 Com
PWM1

42
43

44
45
46

47

48

24VAC Com
DI12
DI11
DI10
DI9
DI8
DI7

49
50
51
52
53
54
55
56

DI 3/4/5/6/ Com
DI6
DI5
DI4
DI3
DI2

DI1

9VDC

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

D09

D08

D07

D06

D05

D04

D03

D02

D01

J8

J2

J10

J9

J
7

A23 A13

A1

1

A21

A12

A25

A22

A32

A31

A35

A14

A24

A34

A33

A15

1

2

3

4

5

7

8

9

10

6

11

12

13

16

15

14

17

20

19

18

SHC

Secondary Unit
Heat/Cool

SE

Secondary Unit
Enable

LV

Load Valve
Output

L

Alarm

X1 Acc 1

X2 Acc 2

PO

Primary Load
Over-ride Output

SN

Secondary
24VAC Input

R

24VAC

ES

Emergency
Shutdown

9DC

9 VDC - Use
for CP and ES

CP

Compressor
Proving Switch

SF Source Flow

Proving Switch

O

Rev Valve

Y1 Comp 1

LF

Load Flow
Proving Switch

POI Primary Load

Over-ride Input

C

24V COM

18

17

16

15

14

12

11

10

9

13

8

7

6

3

4

5

2

1

Black (SHC)

Black (R)

Black (LV)

Black (X2)

Black (X1)

Black (L)

Black (PO)

Black (SE)

Black (SN)

Black (C)

Black (LF)

Black (POI)

Black (O)

Black (SF)

Black (Y1)

Black (ES)

Black (9DC)

Black (CP)

HP

RV

LP

Green/Yellow (67)

Black (37)

Black (22)

Black (26)

Black (26)

Black (40)

Black (40)

Black (38)

Black (38)

Black (35)

Black (35)

Yellow (34)

Black (33)

Black (33)

Black (31)

Black (31)

Black (30)

Black (30)

Black (28)

Black (28)

Black (27)

Black (27)

Black (25)

Violet (24)

Orange (23)

Yellow (21)

Yellow (21)

Yellow (29)

Black (36)

Black (55)

Black (55)

Black (55)

Black (56)

Black (56)

Black (56)

Black (58)

Black (58)

Black (58)

Black (63)

Black (63)

Black (64)

Black (64)

Black (65)

Black (65)

Blue (62)

Gray (61)

Red (60)

Black (59)

Blue (66)

PB2

2

1

3

NOTE 1

NOTE 2

NOTE 5

Black (53)

Black (53)

Black (53)

NOTE 5

NOTE 6

Black (57)

Black (57)

NOTE 6

Black (57)

CC

Green/Yellow (72)

ES

Emergency
Shutdown

9DC

9 VDC - Use
for CP and ES

CP

Compressor
Proving Switch

SF

Source Flow
Proving Switch

O

Rev Valve

Y1

Comp 1

SHC

Secondary Unit
Heat/Cool

SE

Secondary Unit
Enable

LV Load Valve Output

L

Alarm

X1 Acc 1

X2 Acc 2

PO

Primary Load
Over-ride Output

SN

Secondary
24VAC Input

R

24VAC

LF

Load Flow
Proving Switch

POI

Primary Load
Over-ride Input

C

24V COM

TB

Field Connection Diagram

(For units using Set Point control mode

with or without a secondary unit.)

To Primary Load Over-ride Input

(POI) of secondary unit.

To Y1 input of secondary unit.

To R from secondary unit.

To O input of secondary unit.

NOTE 7

NOTE 5

NOTE 6

NOTE 8

ES

Emergency
Shutdown

9DC

9 VDC - Use
for CP and ES

CP

Compressor
Proving Switch

SF

Source Flow
Proving Switch

O

Rev Valve

Y1

Comp 1

SHC

Secondary Unit
Heat/Cool

SE

Secondary Unit
Enable

LV Load Valve Output

L

Alarm

X1 Acc 1

X2 Acc 2

PO

Primary Load
Over-ride Output

SN

Secondary
24VAC Input

R

24VAC

LF

Load Flow
Proving Switch

POI

Primary Load
Over-ride Input

C

24V COM

TB

Field Connection Diagram

(For units using aqua stat control

mode.)

NOTE 7

NOTE 5

NOTE 6

NOTE 8

Aqua Stat Y1

NOTE 9

Thermistor

Relay coil

Switch - High pressure

Switch - Low pressure

Factory low voltage wiring

Factory line voltage wiring

Field low voltage wiring
Field line voltage wiring

Optional block

Internal junction

Field wire lug

Ground

Notes:

L1

Relay Contacts-

N.O., N.C.

Field Zone Sensor Wiring

Open Jumper

Closed Jumper

T

SFS - Source Flow Proving Switch

LFS - Load Flow Proving Switch

TB - Terminal Board

RV - Reversing Valve coil

LP - Low pressure switch

HP - High pressure switch

ELT - Entering Load Water Temp

ES - Emergency Shutdown

CP - Compressor Proving

Compressor contactor

CC -

LFD - Load Freeze Detection

Source Freeze Protection

SFP -

LLT - Leaving Load Water Temp

EST - Entering Source Water Temp

LST - Leaving Source Water Temp

Legend

Polarized connector

1 2 3

P

NOTE 3

Compressor

G

CC

T1

L1

T2

L2

T3

L3

T1

T2

T3

Blue

Black

Unit

Power Supply

Red

380-420/50/3

Blue

420V

Transformer

Red 380V

NOTE 1

1 - Switch Blue and Red wires for 380V operation
2 - Disconnect for -9 degree C load side freeze detection
3 - Disconnect for -9 degree C source side freeze detection
4 - Acc 1 and ACC 2 outputs are cycled with the compressor.
5 - R, C, Y1, and O inputs are for use with an aqua stat.
6 - If no flow proving switch is being used on the load side, the LF terminal on the terminal board must be

jumpered to the R terminal for the unit to operate.

7 - If no flow proving switch is being used on the source side, the SF terminal on the terminal board must

be jumpered to the R terminal for the unit to operate.

8 - A closed contact will enable the emergency shutdown input (ES) and the compressor proving input (CP).
9 - Primary over-ride input (POI) on a primary unit must be wired to R through anormally open contact. If the

POI input is on a secondary unit connect the Primary Over-ride output (PO) from the primary unit to the

POI terminal on the secondary unit.

10 - Apply 24VAC to the O terminal for cooling.

Orange (39)

Violet (70)

Black (54)

PB1

2
1

3

Black (20)

Black (19)

Black (18)

Black (17)
Black (16)

Black (15)

Black (14)

Black (13)

Black (12)

Black (11)
Black (10)

Black (9)

Black (8)

Black (7)

Black (5)

Black (6)

Black (3)

Black (4)

Black (2)

Black (1)

Advertising