Fluke 117 User Manual

Page 22

Advertising
background image

114, 115, and 117
Users Manual

20

Certifications ............................................................UL,

P

, CSA, TÜV,

; (

N10140), VDE

IP Rating (dust and water protection)

.........................

IP42

Table 1. Accuracy Specifications

Function Range

Resolution

Accuracy

± ([% of Reading] + [Counts])

Model

DC millivolts

600.0 mV

0.1 mV

0.5 % + 2

114,
115, 117

DC Volts

6.000 V
60.00 V
600.0 V

0.001 V
0.01 V
0.1 V

0.5 % + 2

114,
115, 117

DC, 45 to 500 Hz

500 Hz to 1 kHz

Auto-V LoZ

[1]

True-rms

600.0 V

0.1 V

2.0 % + 3

4.0 % + 3

114, 117

45 to 500 Hz

500 Hz to 1 kHz

AC millivolts

[1]

True-

rms

600.0 mV

0.1 mV

1.0 % + 3

2.0 % + 3

114,
115, 117

A

C Volts

[1]

True-rms

6.000 V
60.00 V
600.0 V

0.001 V
0.01 V
0.1 V

1.0 % + 3

2.0 % + 3

114,
115, 117

Advertising
This manual is related to the following products: