Installation, Operating heater, Continued – Desa VP600BA EN User Manual

Page 10

Advertising
background image

110720-01D

10

For more information, visit www.desatech.com

For more information, visit www.desatech.com

INSTALLATION

Continued

Propane/LP
Supply Tank

Control
Valve Location

Figure 16 - Checking Gas Joints for Propane/LP Gas

Figure 15 - Checking Gas Joints for Natural Gas

Control Valve Location

Gas
Meter

Equipment
Shutoff Valve

3.

Check all joints from gas meter for natural or propane/LP
supply to equipment shutoff valve (see Figure 17 or 18).
Apply a noncorrosive leak detection fluid to all joints. Bubbles
forming show a leak.

4.

Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.

Open equipment shutoff valve (see Figure 14, page 9).

2.

Open main gas valve located on or near gas meter for natural
gas or open propane/LP supply tank valve.

3.

Make sure control knob of heater is in the OFF position.

4.

Check all joints from equipment shutoff valve to control valve
(see Figures 15 and 16). Apply a noncorrosive leak detection
fluid to all joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater pages 10 through 14).
Check the rest of the internal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to Appliance, pages 11,
12 or 14, depending on your model).

8.

Replace front panel.

OPERATING HEATER

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions

exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand.

When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area

for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire de-

partment.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information above.

2.

Make sure equipment shutoff valve is fully open.

3.

Turn control knob clockwise

Clockwise

to the OFF position.

4.

Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information, above. If you don’t smell
gas, go to the next step.

5.

Press in control knob and turn counterclockwise

C-clockwise

to the PILOT position. Keep control knob pressed in for
five (5) seconds (see Figure 17, page 11).

Note:

You may be running this heater for the first time

after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
• If control knob does not pop up when released, contact a

qualified service person or gas supplier for repairs.

MANUAL CONTROL

BLUE FLAME MODELS

INSTALLATION

Checking Gas Connections (Cont.)

OPERATING HEATER (Manual Control Blue Flame Models)

For Your Safety Read Before Lighting
Lighting Instructions

Equipment
Shutoff Valve

Advertising
This manual is related to the following products: