Nexen 5H45PSE 910225 User Manual
Page 7
7
FORM NO. L-20255-E-0213
LUBRICATION
CAUTION
LUBRICATOR DRIP RATE SETTINGS
NOTE
Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance
and life. All seals in Nexen pneumatically operated devices are lubricated for life, and do not require
additional lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized
air, forcing an oil mist into the air chamber. This is acceptable, but care must be taken to ensure once
an air mist lubrication system is used, it is continually used over the life of the product as the oil mist
may wash free the factory installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
Nexen product's bearings are shielded and pre-lubricated, and require no further lubrication.
These settings are for Nexen supplied
lubricators. If you are not using a Nexen
lubricator, calibration must follow the
manufacturer's suggested procedure.
1. Close and disconnect the air line from the unit.
2. Turn the Lubricator Adjustment Knob counterclockwise
three complete turns.
3. Open the air line.
4. Close the air line to the unit when a drop of oil forms
in the Lubricator Sight Gage.
5. Connect the air line to the unit.
6. Turn the Lubricator Adjustment Knob clockwise until
closed.
7. Turn the Lubricator Adjustment Knob counterclockwise
one-third turn.
8. Open the air line to the unit.
NOTE
For quick response, Nexen recommends
a quick exhaust valve and short air lines
between the Control Valves and the unit.
Align the air inlet ports to a down position
to allow condensation to drain out of the air
chambers of the product.
AIR CONNECTIONS
All Nexen pneumatically actuated devices require clean and
dry air, which meets or exceeds ISO 8573.1:2001 Class
4.4.3 quality.
The following is a common air supply scheme used with this
product. This is an example and not an all-inclusive list. All
air circuits to be used with this product must be designed
following EN983 guidelines.
CAUTION
CAUTION
Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.
To prevent hose breakage, rest the hose against a support
mounted parallel to the Tooth Clutch center line to stop
rotation.
NOTE
Use only flexible hose or tubing when making
air line connections. Rigid pipe or tubing
connected directly to the Tooth Clutch will
prevent proper actuation of the Tooth Clutch.