TROUBLESHOOTING

Size

Max RPM

5H30

3700

5H35

3200

5H45

3000

5H50

3000

5H60

2400

5H80

2000

5H100

1000

TABLE 2

WARNING

Never exceed maximum operating speeds
listed for your product (See Table 2).

WARNING

Ensure proper guarding of the product is
used. Nexen recommends the machine
builder design guarding in compliance
with OSHA 29 CFR 1910 “Occupa-
tional Safety and Health Hazards.”

The temperature limits for this product line
are 4.5º - 100º C (40º-220º F).

CAUTION

PROBLEM

PROBABLE CAUSE

SOLUTION

Failure to Engage

Damaged engagement springs

Contact Nexen.

Unexhausted air due to control valve
malfunction

Replace control valve.

Lack of lubrication in the air chamber

Check air chamber lubrication. (See
LUBRICATION section.)

Using a rigid coupling connected directly
to the Drive Flange

Contact Nexen.

Failure to Disengage

Control valve malfunction or low air
pressure

Check system for air leaks or replace
control valve.

Using a rigid pipe or tubing for air line
connections

Use flexible tubing for air line
connections.

Using a rigid coupling connected directly
to the Drive Flange

Contact Nexen.

Lack of lubrication in the air chamber

Check air chamber lubrication. (See
LUBRICATION section.)

Tooth Wear or Clicking Sound

Excessive engagement RPM, or
unintentional disengagement due to
torque overload

Contact Nexen for specifications.

Bearing Failure

Stay within specified speed limits as specified in the OPERATIONS SECTION.
Avoid applying excessive overhung loads to Pilot Mount 5HP Tooth clutches. Wide
pulleys or sprockets which extend beyond the end of the clutch will increase the
radial load and reduce bearing life.