Nexen 4K Hinge Top 845100 User Manual

Page 6

Advertising
background image

3

FORM NO. L-20014-L-0210

LUBRICATION

CAUTION

LUBRICATOR DRIP RATE SETTINGS

NOTE

Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance and

life. All seals in Nexen pneumatically operated devices are lubricated for life, and do not require additional

lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized air,

forcing an oil mist into the air chamber. This is acceptable, but care must be taken to ensure once an air

mist lubrication system is used, it is continually used over the life of the product as the oil mist may wash

free the factory installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.

These settings are for Nexen supplied
lubricators. If you are not using a Nexen
lubricator, calibration must follow the
manufacturer's suggested procedure.

1. Close and disconnect the air line from the unit.

2. Turn the Lubricator Adjustment Knob

counterclockwise three complete turns.

3. Open the air line.

4. Close the air line to the unit when a drop of oil forms

in the Lubricator Sight Gage.

5. Connect the air line to the unit.

6. Turn the Lubricator Adjustment Knob clockwise until

closed.

7. Turn the Lubricator Adjustment Knob

counterclockwise one-third turn.

8. Open the air line to the unit.

AIR CONNECTIONS

The following is a common air supply scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must
be designed following EN983 guidelines.

All Nexen pneumatically actuated devices require clean,
dry air that meets or exceeds ISO 8573.1:2001 Class
4.4.3 to quality.

CAUTION

Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.

NOTE

For quick response, Nexen recommends a quick

exhaust valve and short air lines between the

Control Valves and the unit. Align the air inlet

ports to a down position to allow condensation

to drain out of the air chambers of the product.

Advertising