AIR CONNECTIONS

NOTE

For quick response, Nexen recommends a quick exhaust

valve and short air lines between the Control Valves and

the product. Align the air inlet ports to a down position

to allow condensation to drain out of the air chambers

of the product.

CAUTION

Low air pressure will cause slippage and

overheating. Excessive air pressure will

cause abrupt starts and stops, reducing

product life.

All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.

Air Pressure (Gage) Limits

6.9 Bar (100 PSI) Absolute Max.

0 Bar (0 PSI) Absolute Min.

The following are common air supply schemes used with
this product. These are examples and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.