Electrical connections, Specifications, F. [0 – Nexen UH 01 912153 User Manual

Page 6: C] cable length ft. [5 m] figure 9

Advertising
background image

FORM NO. L-21233-A-0706

6

1

2

3

4

5

R E D

G R E E N

YE LLOW

WH ITE

B LAC K

+15 VD C

C O M

-15 VD C

0-3 00 mV

C O M

Green / Yellow Shield

P OW E R S U P P LY

O UTP UT S I G NAL

ELECTRICAL CONNECTIONS

Using 16 Ft. [5 m] cable provided, connect UH01 to
the web guide controller according to the instructions
provided with the controller (See Figure 8).

For greater static electricity resistance, connect the sensor
housing’s earth terminal (M4) to a machine frame ground
near the sensor (See Figure 9)

FIGURE 8

SPECIFICATIONS

Frequency Response ................................................. 200 Hz
Sensing Gap ................................................1.89 In. [48 mm]
Measuring Width ............................................0.31 In. [8 mm]
Sensitivity ...................................................0.004 In. [0.1 mm]
Power Supply ..............+15 VDC/100mA -15 VDC/50mA
Output .............................................OPEN, 300 mVDC (Lo)
.....................................................................OPEN, 5 VDC (Hi)
............................................... BLOCkED, 0 mVDC (Lo & Hi)
Weight ................................................................ 1 Lb. [.45 kg]
Ambient Temperature .................. 32

o

- 120

o

F. [0

o

- 50

o

C]

Cable Length ........................................................ 16 Ft. [5 m]

FIGURE 9

Earth terminal (M) Type D

earth connection or better