Log Box-DA
Note: The case cover should not be opened unless battery replacement is required. If this is the case,
the cover must be properly tightened back in its place such as to assure the IP67 / 68 protection.
IP67/IP68 external connectors
CHANNEL CABLE (RIGHT)
CONNECTION
Blue
Channel 1 - IN1 - positive (+)
Black
Channel 1 - GND - negative (-)
White
Channel 2 - IN2 - positive (+)
Brown
Channel 2 - GND - negative (-)
SWITCH CABLE (LEFT)
CONNECTION
Blue
Transducer +V TRANS
Black
External Battery (-BAT)
White
External Battery (+BAT)
Brown
Not Connected