Mechanical outline – Applied Motion 7080 User Manual

Page 3

Advertising
background image

Introduction

Thank you for selecting an Applied Motion Products motor control. We hope our
dedication to performance, quality and economy will make your motion control
project successful. If there's anything we can do to improve our products or help
you use them better, please call or fax. We'd like to hear from you. Our phone
number is (800) 525-1609 or you can reach us by fax at (831) 761–6544.

Features
• Drives NEMA sizes 14 through 42 step motors
• MOSFET pulse width modulation switching amplifiers (3 state)
• Phase current from 0.8 to 7.0 amps/phase (switch selectable, 32 settings)
• Step, direction and amplifier enable inputs, optically isolated
• Microstepping from full step through 1/ 254 (switch selectable, 16 settings)
• Over temperature and over current (short circuit) protection
• Idle current reduction (50% or 0%, switch selectable)
• Fault output, optically isolated

Block Diagram

-3-

-14-

Mechanical Outline

2.45"

5.70"

0.150"

3.00"

0.25"

6.00"

0.15"

5.70"

2.00"

.720"

1.345"

6x Ø.170

Fault

Self Test

Monitor

PWM Clock

25 kHz

PWM Power

Amplifier

PWM Power

Amplifier

motor phase A

motor phase B

18-80VDC

6.3A fuse

Voltage

Regulator

idle

current

reduction

current

selector

Optical

Isolation

step
direction
enable

power

light

overcurrent

light

overtemp

light

fault output

34567

Microstep

Sequencer

4

3

2

1

resolution

selector

2

1

Advertising