3 Installation/Connections

3.1 Connecting the Power Supply

Use 16 to 20-gauge wire to connect the TSM17C to a power supply. It contains an internal fuse

connected to the “+” terminal that is not user replaceable. If a user serviceable fuse is desired,

install a 6.3 amp fast acting fuse in line with the “+” power supply lead.

Be careful not to reverse the wires. Reversing the connection may open the internal

fuse on the drive and void the warranty.

Applied Motion Products offers two matched power supplies for use with the TSM17C.

A 24VDC, 150W(P/N PS150A24) and a 48VDC 320W(P/N PS320A48).

These power supplies have current over load capability making them ideal for use.

(To use with a switch power supplier, a RC880 regen must be connected in system)

The RC880 regeneration clamp is for use where regeneration from the motor may cause damage

to the drive. In these cases the RC880 is connected between the drive and power supply and

absorbs regenerated energy.

To Earth Ground

To Power Supply-

To Power Supply+

RC880