Operation – Desa VVDR24 User Manual

Page 14

Advertising
background image

www.desatech.com

124183-01B

14

GAS SHUTOFF

VALVE OPERATION

Flame Adjustment
Adjust the flame ON/OFF by turning gas shut-
off valve counterclockwise

to open or

clockwise

to close, as necessary.

Shutting Off Appliance
Turn gas shutoff valve clockwise

to

OFF position.

CURING

LOGS

During the 2-3 hour appliance break-in period,
you may detect an odor from the appliance
as various paints and compounds used in
manufacturing of this log set cure. This is a
normal and temporary situation that is not
cause for alarm. However, you may want to
provide extra ventilation to the room during
this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1

hour.

• Burn logs in consecutive 1 hour periods

raising the flame an additional 2" to full
flame height for a total of three hours.

OPERATING

INSTRUCTIONS

FOR GA9050A-1

Note: Operation instructions for GA9050A-1
Remote Ready Valve/Pilot Kit will be included
with the kit.
1. STOP! Read the safety information,

column 1.

2. Make sure equipment shutoff valve is fully

open.

3. Press in and turn control knob clockwise

to the OFF position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas around log set and
near floor. If you smell gas, STOP! Refer
to the National Fuel Gas Codes, ANSI
Z233.1/NFPA 54, Air for Combustion and
Ventilation
. If you don’t smell gas, go to
the next step.

5. Turn control knob counterclockwise

to the PILOT position and press

in. Keep control knob pressed in for five
(5) seconds.

OPERATION

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: Keep flue open

when operating unit.

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

BEFORE LIGhTING smell all around the ap-
pliance area for gas. Be sure to smell next
to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information,

above.

2. Turn gas shutoff valve to OFF.
3. Wait five (5) minutes to clear out any gas.

If you then smell gas STOP! Follow the
safety information, above. If you don't
smell gas, go on to the next step.

4. Light a match and lay it on top of pan

material about 2" from end of supply side
of pan

5. Slowly turn gas shutoff valve ON until

burner ignites. If burner doesn’t ignite
within 10 seconds with match burning,
turn shutoff valve OFF and repeat steps
1 through 4 again.

Advertising