Troubleshooting – Desa VVDR24 User Manual

Page 17

Advertising
background image

www.desatech.com

124183-01B

17

POSSIBLE CAUSE

1. Gas supply turned off or

equipment shutoff valve
closed

2. Control knob not in PILOT

position

3. Control knob not pressed

in while in PILOT position

4. Air in gas lines when in-

stalled

5. Pilot adjustment screw

closed

6. Pilot is clogged

7. Low gas pressure

1. Control knob not fully

pressed in

2. Control knob not pressed

in long enough

3. Equipment shutoff valve

not fully open

4. Pilot flame not touching

thermocouple, which al-
lows thermocouple to cool,
causing pilot flame to go
out. This problem could
be caused by one or both
of the following:

A) Low gas pressure
B) Dirty or partially clogged

pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged
7. Control valve damaged

1. Burner orifice clogged
2. Inlet gas pressure is too

low

3. Thermocouple leads dis-

connected or improperly
connected

1. Pilot flame needs adjusting

2. Wrong pilot orifice

REMEDY

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while

in PILOT position

4. Continue holding down

control knob. Repeat ignit-
ing operation until air is
removed

5. Adjust pilot flame for ap-

proximately 2" blue flame

6. Clean pilot (see Cleaning

and Maintenance, page 15)
or replace pilot assembly

7. Replace gas control

1. Press in control knob fully

2. After pilot lights, keep con-

trol knob pressed in 30
seconds

3. Fully open equipment shut-

off valve

4. A) Contact local natural gas

company

B) Clean pilot (see Cleaning

and Maintenance, page 15)
or replace pilot assembly

5. Hand tighten until snug,

then tighten 1/4 turn more

6. Replace thermocouple
7. Replace control valve

1. Clean burner orifice
2. Contact local natural or

propane/LP gas company

3. Reconnect leads

1. Adjust pilot flame for ap-

proximately 2" blue flame

2. Replace pilot orifice set

OBSERVED PROBLEM

When ignitor button is pressed,
there is spark at pilot but no
ignition (GA9050A-1 Only)

Pilot lights but flame goes out
when control knob is released
(GA9050A-1 Only)

Burner does not light after pilot
is lit (GA9050A-1 Only)

Delayed ignition burner
(GA9050A-1 Only)

TROUBLEShOOTING

Continued

Advertising
This manual is related to the following products: