Installation, Continued, Flue opening specifications – Desa VVDR24 User Manual

Page 6

Advertising
background image

www.desatech.com

124183-01B

6

BURNER ORIFICE

LOG

NATURAL PROPANE/LP

SIZE

IN.

NUM.

IN.

NUM.

VVSR18, FVSR18,

VVDR18, FVDR18

0.120

31

0.073

49

VVSR24, FVSR24

VVDR24, FVDR24

0.129

30

0.086

44

VVDR30, FVDR30 0.1405 28

0.089

43

Model

Burner

Description

B

tu

/Hr

In

p

u

t

Natural Gas

B

tu

/Hr

In

p

u

t

P

ro

p

an

e/

L

P

Gas

Minimum

V

en

t

Opening

VVSR18

FVSR18

18"

Single 50,000 40,000

8" dia.

VVSR24

FVSR24

24"

Single 60,000 50,000

8" dia.

VVDR18

FVDR18

18"

Dual

55,000 45,000

8" dia.

VVDR24

FVDR24

24"

Dual

65,000 55,000

8" dia.

VVDR30

FVDR30

30"

Dual

70,000 60,000

8" dia.

*Add 6" if safety valve/pilot is used
**At depth indicated

FUEL INLET PRESSURE

SPECIFICATIONS (W.C.)

Min.

Max.

NG

5.5"

10.5"

LP

11"

13"

Figure 2 - Technical Information Charts

MINIMUM FIREBOX SIZES

Models: VVSR18, FVSR18, VVDR18, FVDR18

Front Width* Back Width** Depth

Height

28"

16"

14"

18"

Models: VVSR24, FVSR24, VVDR24, FVDR24

Front Width* Back Width** Depth

Height

29

3

/

4

"

17"

15

1

/

2

"

18"

Models: VVDR30, FVDR30

Front Width* Back Width** Depth

Height

36"

27"

18"

18"

INSTALLATION

Continued

NOTICE: Installation, service,

and repair of this appliance must

be performed by a qualified in-

staller, service agency, company

or gas supplier experienced with

this type of gas appliance. Only

factory authorized components

listed in these instructions may

be used in accordance with the

manufacturer’s instructions and

all codes and requirements of

the authority having jurisdic-

tion. Any modifications to this

kit, or use of unauthorized

components or accessory items

will void the manufacturer’s

warranty, and may result in a

hazardous condition.

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed
only in a solid-fuel burning fireplace with a
working flue and constructed of noncombus-
tible material.
The charts in Figure 2, indicate technical
information regarding the installation of your
gas log set. Please make sure that all of the
specifications shown are applicable before
installation is attempted.
The fireplace must include a working flue and
venting system with the minimum openings
shown in the Figure 2.

Advertising
This manual is related to the following products: