Cleaning and maintenance, Operation, Continued to turn off gas to appliance – Desa VVDR24 User Manual

Page 15: Figure 19 - ignitor and control knob

Advertising
background image

www.desatech.com

124183-01B

15

Note: You may be running this log set
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds. This will
allow air to bleed from the gas system.
• If control knob does not pop up when

released, contact a qualified service
person or gas supplier for repairs.

6. With control knob pressed in, push down

and release ignitor button. This will light
pilot. The pilot is attached to the rear of
the front burner. If needed, keep pressing
ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match.

7. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob.

Note: If pilot goes out, repeat steps 3
through 7, page 14.

8. Turn control knob counterclockwise

to the ON position. Burner should

light. If burner does not light, call a quali-
fied service person.

9. To leave pilot lit and shut off burners only,

turn control knob clockwise

to the

PILOT position.

Ignitor

Control Knob Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

TO LIGHT

ON

ON

FROM "PILOT" POSITION

SLIGHT

PUSH

T

O

TURN OFF

PULL

PUSH

T

O LIGHT

FROM "PILOT" POSITION

SLIGHT

PUSH

T

O

TURN OFF

PULL

PUSH

T

O LIGHT

ON

OFF

On

Off

OFF

OFF

Figure 19 - Ignitor and Control Knob

OPERATION

Continued

TO TURN OFF GAS

TO APPLIANCE

1. Turn control knob clockwise

to the

PILOT position.

2. Press in and turn control clockwise

to the OFF position.

3. Close equipment shutoff valve.

CLEANING AND MAINTENANCE

Figure 20 - Thermocouple and Pilot

Pilot
Burner

Thermocouple

• Keep the area around the log set clean and

clear of debris.

• Occasionally, you may use a soft bristle

brush to clean logs.

• Once every year a qualified agency or certi-

fied chimney sweep should examine and
clean the venting system of the fireplace.

Advertising