Stove and direct-vent burner system installation, Continued – Desa AMITY SDVBND User Manual

Page 23

Advertising
background image

112126-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

23

23

W

R

STOVE AND DIRECT-VENT
BURNER SYSTEM
INSTALLATION

Continued

INSTALLING OPTIONAL WALL MOUNTED
THERMOSTAT - GWMT1

WARNING: Installation must be done by a qualified

installer familiar with low voltage wiring procedures.

WARNING: Do not connect this thermostat to any

electrical source! Electrical shock and/or fire hazard
will occur.

1.

Open lower door panel. The valve is attached to the underside
of the burner system assembly.

2.

Disconnect from the valve the wires running from the ON/
OFF switch.

3.

Connect one terminal of the wire for the wall thermostat to the
THTP terminal on the valve. Connect remaining wire terminal
to the TH terminal on the valve. Make sure that the wire termi-
nals are in the positions on the unit as pictured in Figure 45,
page 22. If wires are not connected as shown the thermostat
will not work.

4.

Route the wire to a convenient location to mount your thermo-
stat (no outside wall). IMPORTANT: The wire must not ex-
ceed 25 feet in length. The thermostat should be mounted 54"
above the floor in a location where there is good air circula-
tion. Avoid heat sources such as lamps, direct sunlight, fire-
place, or heat and air conditioning ducts.

5.

Gently remove the cover of the thermostat from the base. Grasp
the sides of the cover firmly and pull to separate from the base.

6.

Feed the electrical wires through the rectangular slots (from
the back) on each side of the base (see Figure 46).

WARNING: Do not connect this thermostat to a

power source. Electrical shock and/or fire hazard
will occur.

Figure 46 - Back View of
Thermostat Base

Feed wires through
rectangular slots

Figure 47 - Thermostat
Base Terminal “W” and “R”

Terminal “W”

Terminal “R”

7.

Connect one bare wire end to each terminal (“W” and “R”) of
the thermostat base (see Figure 47).

8.

Install the base to the wall with screws provided with thermostat.

9.

Move the temperature adjustment back and forth to insure the
bimetal is free from restrictions.

10. Replace the cover onto the base. (Upon installation, the ther-

mostat must be allowed to stabilize at room temperature for
a minimum of 30 minutes for proper operation.)

11. Set the temperature adjustment to the desired setting. This ther-

mostat has been electronically calibrated at the factory. No ad-
justment or leveling is necessary.

INSTALLING OPTIONAL WIRELESS HAND-
HELD REMOTE CONTROL ACCESSORIES -
(C)GHRCB AND (C)GHRCTB SERIES

NOTICE: Use only alkaline batteries (not included).

Installing Remote Receiver and 9-volt Alkaline
Battery

1.

Open bottom door on stove body.

2.

Disconnect wires from THTP and TH on control valve that
lead to the switch (see Figure 45, page 22). Discard switch
plate, screws, and nuts.

3.

Install 9-volt battery (not included) into receiver battery clip
and connect to terminals (see Figure 48).

Figure 48 - Installing Battery in Receiver

9-Volt
Battery

Receiver

Battery
Clip

Terminal
Wires

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Installing Optional Wall Mounted Thermostat - GWMT1

Installing Optional Wireless Hand-Held Remote Control Accessories - (C)GHRCB and (C)GHRCTB Series

Advertising
This manual is related to the following products: