33

33

Figure 65 - Blower Wiring Diagram for Thermostat-Controlled
Models

WIRING DIAGRAM

CAUTION: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.

SPECIFICATIONS

WIRING DIAGRAM

REPLACEMENT PARTS

SPECIFICATIONS

SDVBND

SDVBPD

21,000-30,000 Btu/h

20,000-28,000 Btu/h

Gas Type

Natural

Propane/LP

Ignition

Piezo

Piezo

Manifold Pressure

3.5" w.c.

10.0" w.c.

Minimum Inlet Supply Pressure

5.0" w.c.

11.0" w.c.

Thermal Efficiency

70%

70%

Dimension, Inches/mm (HxWxD)

Stove and Burner System*

27" x 21

1

/

2

" x 18"

27" x 21

1

/

2

" x 18"

68.6 x 54.6 x 45.7 cm

68.6 x 54.6 x 45.7 cm

Carton

23

3

/

4

" x 33

1

/

2

" x 23

1

/

2

"

23

3

/

4

" x 33

1

/

2

" x 23

1

/

2

"

60.3 x 85.1 x 59.7 cm

60.3 x 85.1 x 59.7 cm

Weight, lbs/kg

Burner System

70 lbs/31.8 kg

70 lbs/31.8 kg

Shipping

75 lbs/34 kg

75 lbs/34 kg

* When installed in a model SCIVF/PSCIVF series cast iron stove body.

REPLACEMENT PARTS

Note:

Use only original replacement parts. This will protect your

warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can not supply
original replacement part(s), call DESA’s Technical Service De-
partment at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your burner system and stove

how burner system or stove was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can not supply
original replacement part(s), call DESA at 1-866-672-6040 for
referral information.

When calling DESA, have ready

model number of your burner system and stove

the replacement part number

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black