Installation, Continued – Desa VML27NR User Manual

Page 7

Advertising
background image

111115-01D

7

7

For more information, visit www.desatech.com

For more information, visit www.desatech.com

INSTALLATION AND CLEARANCES

(Vent-Free Operation Only)

WARNING: Maintain the minimum clearances. If

you can, provide greater clearances from floor, ceil-
ing, and adjoining wall.

WARNING: Never install the heater

• in a bedroom or bathroom unless installed as a

vented appliance, see page 9

• in a recreational vehicle
• where curtains, furniture, clothing, or other flam-

mable objects are less than 42 inches from the
front, top, or sides of the heater

• in high traffic areas
• in windy or drafty areas

WARNING: Seal any fresh air vents or ash clean-

out doors located on floor or wall of fireplace. If not,
drafting may cause pilot outage or sooting. Use a
heat-resistant sealant. Do not seal chimney flue
damper.

CAUTION: This heater creates warm air currents.

These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
coverings or operating heater where impurities (such
as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls or cause odors.

IMPORTANT:

Vent-free heaters add moisture to the air. Although

this is beneficial, installing heater in rooms without enough venti-
lation air may cause mildew to form from too much moisture. See
Air for Combustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use only the correct type of gas (natural or propane/LP). If your gas
supply is not the correct gas type, do not install heater. Call dealer
where you bought heater for proper type heater.

LOG SIZING REQUIREMENTS

Log

Minimum Firebox

Size

Height

Depth

Width

27"

17"

19"

32"

MINIMUM FIREPLACE CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

27"

16"

42"

Carefully follow the instructions below. This will ensure safe
installation into a masonry, UL127-listed manufactured fireplace,
or listed vent-free firebox.

Minimum Clearances For Side Combustible Mate-
rial, Side Wall, and Ceiling

A. Clearances from the side of the fireplace cabinet to any com-

bustible material and wall should follow diagram in Figure 4.

Example:

The face of a mantel, bookshelf, etc. is made of

combustible material and protrudes 3

1

/

2

" from the wall. This

combustible material must be 4" from the side of the fireplace
cabinet (see Figure 4).

Note:

When installing your gas logs into a manufactured firebox,

follow firebox manufacturer’s instructions for minimum clear-
ances to combustible materials.

B. Clearances from the top of the fireplace opening to the ceiling

should not be less than 42 inches.

Figure 4 - Minimum Clearance for Combustible to Wall

*Minimum 16 inches from Side Wall

*

Example

INSTALLATION

Check Gas Type

Installation and Clearances

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a
vented product. If so, you must always run heater with
chimney flue damper open. If running heater with
damper open, noncombustible material above fire-
place opening is not needed. Go to

Installing Damper

Clamp Accessory for Vented Operation, page 9.

Advertising