Owner’s manual, Service procedures – Desa B115T User Manual

Page 7

Advertising
background image

7

104193

OWNER’S MANUAL

Figure 7 - Pressure Gauge Plug Removal

Fan

Motor

Figure 6 - Air Output, Air Intake, and Lint
Filters

Flush

Setscrew

Motor
Shaft

Figure 5 - Fan Cross Section

SERVICE
PROCEDURES

WARNING: Never service

heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.

UPPER SHELL REMOVAL

1.

Remove screws along each side of
heater using 5/16" nut-driver. These
screws attach upper and lower shells
together.

2.

Lift upper shell off.

3.

Remove fan guard.

FAN

IMPORTANT:

Remove fan from motor shaft

before removing motor from heater. The
weight of the motor resting on the fan could
damage the fan pitch.

1.

Remove upper shell (see above).

2.

Use 1/8" Allen wrench to loosen set-
screw which holds fan to motor shaft.

3.

Slip fan off motor shaft.

4.

Clean fan using soft cloth moistened
with kerosene or solvent.

5.

Dry fan thoroughly.

6.

Replace fan on motor shaft. Place fan
hub flush with end of motor shaft (see
Figure 5).

7.

Place setscrew on flat of shaft. Tighten
setscrew firmly (40-50 inch-pounds).

8.

Replace fan guard and upper shell.

AIR OUTPUT, AIR INTAKE,
AND LINT FILTERS

1.

Remove upper shell (see Upper Shell
Removal,
column 1).

2.

Remove filter end cover screws using
5/16" nut-driver.

3.

Remove filter end cover.

4.

Replace air output and lint filters.

5.

Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 5).

6.

Replace filter end cover.

7.

Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters.

PUMP PRESSURE
ADJUSTMENT

1.

Remove pressure gauge plug from filter
end cover.

2.

Install accessory pressure gauge (part
number HA1180).

3.

Start heater (see Operation, page 5).
Allow motor to reach full speed.

4.

Using a flat blade screwdriver, adjust
pressure. Turn relief valve to right to
increase the pressure. Turn relief valve
to left to decrease the pressure. Set
pump pressure at 5.3 PSI.

5.

Stop heater (see Operation, page 5).

6.

Remove pressure gauge. Replace pres-
sure gauge plug in filter end cover.

Figure 4 - Upper Shell Removal

Upper
Shell

Fan
Guard

Fan Guard

Air Intake Filter

Air Output Filter

Filter End Cover

Lint Filter

Relief
Valve

Pressure
Gauge
Plug

Pressure
Gauge

Figure 8 - Adjusting Pump Pressure

Continued

Advertising