Troubleshooting – Desa BQMV24N User Manual

Page 15

Advertising
background image

www.desatech.com

117423-01A

15

OBSERVED PROBLEM

Dark orange flame in burner dur-

ing burner combustion

Slight smoke or odor during initial

operation

Produces a whistling noise when

burners are lit

White powder residue forming

within burner box or on adjacent

walls or furniture

REMEDY

1. Check burner(s) for dirt

and debris. If found, clean

burner(s) (see Cleaning and

Maintenance, page 12)

2. Replace gas regulator

1. Problem will stop after a few

hours of operation

1. Turn control knob to LO

position and let warm up for

a minute

2. Operate burners until air is

removed from line. Have gas

line checked by local natural

or propane/LP gas company.

3. Observe minimum installation

clearances (see page 6)

4. Clean burners (see Cleaning

and Maintenance, page 12) or

replace burner orifice(s)

1. Heat turned off when using

furniture polish, wax, carpet

cleaners or ism

POSSIBLE CAUSE

1. Not enough air

2. Gas regulator defective

1. Residues from manufacturing

processes and log curing

1. Turning control knob to HI

position when burners are

cold

2. Air is gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice(s)

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc, turn into white

powder residue

TROUBLESHOOTING

Continued

Advertising
This manual is related to the following products: