CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for

your unit. If your gas supply is not correct, do not

instal in fireplace. Call dealer where you bought

the appliance for proper type of appliance.

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

INSTALLATION AND CLEARANCES

Figure 2 shows technical information regarding

the installation of your gas log set. Please make

sure all specifications shown are applicable before

installation is attempted.

LOG SIZING REQUIREMENTS

MINIMUM FIREBOX SIZE

LOG

FRONT REAR* MIN. FLUE

SIZE HEIGHT DEPTH WIDTH WIDTH

SIZE

18"

20"

14"

25" 20.5"

6.5"

24"

20"

14"

29" 24.5"

6.5"

*Measured at 14" depth

Figure 4 - Attaching Damper Clamp

Manufactured

Fireplace

Masonry

Fireplace

Damper

Damper
Clamp

Damper

Damper
Clamp

Damper

VENTING SPECIFICATIONS FOR
INSTALLATION

The fireplace chimney flue and vent must be draft-

ing properly. To check the vent for proper drafting:

Light a tightly rolled newspaper on one end and

place it at the inside front edge of the fireplace.

Observe the smoke and be sure the vent is properly

INSTALLATION

Continued

SPECIFICATIONS (W.C.)

FUEL INLET

MANIFOLD

PRESSURE

PRESSURE

Min. Max.

NG

7"

10.5"

3.5"

LP

11"

14"

10"

FLUE OPENING SPECIFICATIONS

Note:

This vented appliance must be installed only

in a solid-fuel burning or UL127 factory-built fire-

place constructed of noncombustible material and

connected to a working flue. The fireplace chimney

must have a permanent vent opening to outside

with minimum openings shown in Figure 3.

Figure 2 - Technical Information Chart

Figure 3 - Sizes and Clearances

drawing it up the chimney. If the smoke spills out

into the room, extinguish the flame and remove any

obstruction until proper venting is achieved.
The chimney flue damper must be fixed open to pro-

vide a minimum of 32 square inch of free air opening

at all times during operation of the log set. A damper

clamp is included to secure the damper.
The minimum flue sizes shown in Figure 3 are

based on a 6' chimney height using round pipe. Your

minimum flue size will vary based on input rate and

chimney height. Refer to the National Fuel Gas Code

ANSI Z223.1/NFPA 54, Section 6.6 for details.

INSTALLING DAMPER CLAMP

Secure the damper stop clam to the edge of the

damper as shown in Figure 4. If for any reason

this clamp doesn't work on your fireplace, another

suitable clamp or permanent stop must be installed,

or the damper blade must be cut or removed.

Valve Bracket

INSTALLING REMOTE CONTROL
ACCESSORY BRACKET

If installing optional remote control accessory you

will need to install the remote accessory bracket

for the receiver.
Use screws provided to attach bracket to valve

bracket as shown in Figure 5.
Follow installation instructions included with

remote accessory.

Figure 5 - Attaching Remote Bracket to

Valve Bracket

Remote
Bracket