Terminations with 16" slip pipe sections are avail-

able. The RTT-8DM and RTTL-8DM are approved

for flashing installations. When needed, these

adjustable terminations may be used in combina-

tion with the pipe assembly to achieve the correct

chimney height.
Note

: In the rare instance there is a problem with

the side driven rain or wind or the chimney is

not drafting properly, an ADS-8DM (Anti-Draft

Shield) can be used with round terminations.

CHASE INSTALLATIONS

Instructions for chase installations are included

with the chase style termination chosen. In a

multiple chase installation, be sure to provide

adequate distance between terminations to prevent

smoke spillage from one termination to another.

We suggest that terminations be separated at least

24", center to center and stacked at a vertical height

difference of 18" (see Figure 16).
Note:

If a decorative shroud is to be installed,

contact the manufacturer for specifications.

10 FOOT RULE

All flue gas outlet chimney terminations must

extend a minimum of 3 feet in height above the

highest point where it passes through the roof and

must be at least 2 feet above the highest point of

the roof that is within a horizontal distance of 10

feet (see Figure 17).

24" Min.

24" Min.

18"

Min.
Typ.

Figure 16 - Multiple Chase Installation

10'

2' Min.

10'

3' Min.

2' Min.

3' Min.

Level of
Flue Gas
Outlet

Figure 17 - 10 Foot Rule

FINISHING THE FIREPLACE

Combustible materials, such as wallboard, gypsum

board, sheet rock, drywall, plywood, etc. may make

direct contact with sides and top around the fireplace

face. It is important that combustible materials do

not overlap the face itself. Brick, glass, tile or other

noncombustible materials may overlap the front

face provided they do not obstruct essential open-

ings like louvered slots or any other opening. When

overlapping with a noncombustible facing material,

use only noncombustible mortar or adhesive.

Venting inStallatiOn

Continued