Venting inStallatiOn

Continued

14

3

/

8

" Min.

(365 mm)

30" Min.

(762 mm)

1" Min.

(25 mm)

1" Min.

(25 mm)

1" Min.

(25 mm)

Opening "A"

Pitch

Slope Opening "A"

Max.

Used Flashing

Model No.

Flat

1"

V6F-8DM

0-6/12

26.6°

16

1

/

8

"

V6F-8DM

6/12-

12/12

4.0°

20

3

/

8

"

V12F-8DM

FLASHING INSTALLATION (V6F-8DM
OR V12F-8DM)

Determine the flashing to be used with the roof

opening chart. Slide flashing over pipe until base

is flat against roof. Replace as many shingles as

needed to cover exposed area and flashing base.

Secure in position by nailing through shingles

(see Figure 13). DO NOT NAIL THROUGH

FLASHING CONE.
Installing Flashing on a Metal Roof

When installing the flashing on a metal roof, it is

required that putty tape be used between the flashing

and the roof. The flashing must be secured to the roof

using #8 x 3/4" screws and then sealed with roof coat-

ing to prevent leakage through the screw holes. A roof

coating must also be applied around the perimeter of

the flashing to provide a proper seal.

Figure 12 - Roof Opening Measurements

Nail Only
Outer
Perimeter
of Flashing

Storm Collar

Flashing
Cone

Underlap Shingles
at Bottom

Overlap
Shingles Top
and Sides Only

Figure 13 - Flashing Installation

Storm Collar Installation (SC1 or SC2)

Place storm collar over pipe and slide down until

it is snug against the open edge of the flashing (see

Figure 14). Use SC1 for all round terminations and

SC2 for all terminations with slip sections. Apply

waterproof caulk around the perimeter of the collar

to provide a proper seal.

Figure 14 - Storm Collar

Chimney
Pipe

Waterproof
Caulk

Storm
Collar

Flashing

Terminations/Spark Arrestor

The fireplace system must be terminated with the

listed round top or chase terminations. In any case,

refer to the installation instructions supplied with

the termination. The termination approved for this

fireplace are the RT-8DM and RTL-8DM that can

be used for flashing or chase and ET-8DM, ETO-

8DM, ETL-8DM and ETLO-8DM for chase style

termination only. Figure 15 shows an RTL-8DM

round top termination.

CAUTION: Do not seal open-

ings on the rooftop flashing. Fol-

low the installation instructions

provided with the termination

being used.

Attach Bracket
Tabs to
Outer Pipe
(3 Places)
Secure with
Screws

RTL-8D

Level of
Flue Gas
Outlet

Caulk

Collar

Flashing

Underlap
Shingles
Bottom Only

Figure 15 - Termination

Overlap
Shingles Top
and Sides