Storage, Maintenance, Inspecting burner – Desa Btu User Manual

Page 5: Operation

Advertising
background image

www.desatech.com

113325-01C

5

MAINTENANCE

WARNING: Never attempt to

service heater while it is connect-

ed to propane supply, operating,

or hot. Severe burns can occur.

1. Keep heater clean.
2. Inspect heater before each use. Check connec-

tions for leaks. Apply mixture of liquid soap

and water to connections. Bubbles forming

show a leak that must be corrected. Correct

all leaks at once.

3. Inspect hose/regulator assembly before each

use. If hose is highly worn or cut, replace.

4. Have heater inspected yearly by a qualified

service person.

INSPECTING BURNER

WARNING: Heater shell, top,

and heated air from heater is very

hot during operation. Gradually

move in closer to heater to ob-

serve flame color. Do not touch

heater shell or top. Do not get too

close to heated air from heater.

Severe burns could occur.

To check for correct burner flame, look through the

ventilation holes in the top of the heater to see the

burner flame. The burner flame should be mostly

blue with slight yellow coloring on the ends. If

the burner flame is mostly yellow, the primary air

openings on the burner tube under the heater base

may be blocked (see Figure 4).
1. Stop heater (see To Stop Heater) and let cool.
2. Turn heater over to locate the primary air open-

ings on the burner tube (see Figure 4). Remove

any debris blocking the primary air openings.

OPERATION

Continued

Burner
Tube

Primary Air
Openings

Figure 4 - Bottom View of Heater

5. Push in and hold automatic control valve button

(see Figure 3). Push and release piezo ignitor

button. Keep pushing piezo ignitor button until

the burner lights. Hold control knob down

for a maximum of 10 seconds while attempt-

ing ignition. If heater does not light, release

control knob and wait 30 seconds. Repeat

step 5 to start heater. Note: Keep hands and

face away from outlet (around top of shell)

of heater while attempting to start heater.

After ignition, hold control knob down for

approximately 30 seconds. This activates the

automatic control system.

6. If burner will not light after repeated tries,

do not attempt to repair heater. Return heater

to nearest authorized service center or call

DESA Heating Productsʼ Technical Service

at 1-866-672-6040.

7. When burner remains lit, you can turn the heater

regulator knob clockwise to the desired heat

setting. If burner goes out, turn off gas. Check

fuel supply. If fuel supply is OK, restart heater.

TO STOP HEATER

1. Tightly close propane supply valve on propane

tanks by turning clockwise. Wait 15 minutes

for the heater to cool before handling heater.

2. Always remove the gas supply hose from the

heater and the propane tank after each use.

TO RESTART HEATER

1. Wait five minutes after stopping heater.
2. Repeat steps under To Start Heater, page 4.

STORAGE

CAUTION: Disconnect heater

from propane supply tank(s).

1. Do not store heater while attached to propane

tank. Remove the gas supply hose from the

propane tank by turning the fuel gas connector

nut clockwise.

2. Store propane tank(s) in safe manner. Refer

to Chapter 5 of Standard for Storage and

Handling of Liquefied Petroleum Gases, ANSI/

NFPA 58

. Follow all local codes. Always store

propane tanks outdoors. Never store propane

tank in an enclosed area.

3. Place plastic cover caps over brass fittings on

inlet connector and hose/regulator assembly.

4. Store in a dry, clean, and safe place.

Advertising