Factory default, Configuration, Restoring – CUE smartCUE Interfaces User Manual

Page 10: 10 configuration 10 restoring

Advertising
background image

10

smartCUE Interfaces | User Manual | Factory Default

© CUE, a.s. All Rights Reserved. | www.cuesystem.com | [email protected]

Factory Default

Configuration

Every device shipped from the factory is set according to this table.

Wired Models

Wireless Models

Configuration Identification

Name

Empty

Empty

Network

IP address

192.168.1.254

192.168.1.254

Subnet mask

255.255.255.0

255.255.255.0

Default gateway

192.168.1.1

192.168.1.1

Admin Web port

80

80

TCP port 1

10001

10001

TCP port 2

(1)

10002

10002

UDP port

7777

7777

WiFi

Network name (SSID)

-

smartCUE

Network type

-

Ad-Hoc

Channel (Ad-Hoc only) -

9

Security type

-

None

Encryption type

-

None

Security key

-

Empty

Password

Empty (no input required)

Empty (no input required)

(1)

Only for smartCUE-zero, smartCUE-zero-wifi, smartCUE-three, smartCUE-three-wifi

Restoring

The main purpose of this functionality is to regain connection with lost password or unknown IP settings.
To restore the factory default configuration, provide following steps

1. Turn the power off. Disconnect Ethernet cable for wired models or power adapter for wireless models.

2. Press button F.D. located on the front panel and hold it.

1

2

SERIAL

1

2

3

4

DIGITAL I/O

PWR LINK

F.

D.

Button factory default

3. Turn the power on and hold button F.D. at least 7 seconds.

4. Factory default configuration is restored according table above.

Advertising