Setup the Unit

Wired Models

To get access to the factory default configured unit provide following steps

1. Set manually PC Local Area Connection (Ethernet network adapter) to

▪ IP address: 192.168.1.x where x = 1 to 253

▪ Subnet mask: 255.255.255.0

2. Connect the interface to PC. Use crossover cable for direct connection between PC and smartCUE if

your PC ethernet adapter doesn’t support auto-sense.

3. Use standard Internet browser and fill address line with http://192.168.1.254.
4. Provide setup using Admin Web. Use section Configuration / Network to set smartCUE connection to

target network. Settings depends on the network, however typically it is necessary to set

▪ IP address

Wireless Models

The unit uses Ad-Hoc wireless mode for initial setup. To get access to the factory default configured unit

provide following steps

1. Set manually your PC wireless adapter to

▪ IP address: 192.168.1.x where x = 1 to 253

▪ Subnet mask: 255.255.255.0

2. Disable all other PC network adapters which are configured as IP address 192.168.1.x (DHCP or static).
3. Switch on the smartCUE.
4. Connect your PC to wireless network Name: smartCUE
5. Use standard Internet browser and fill address line with http://192.168.1.254.
6. Provide setup using Admin Web. Use section Configuration / Network and Configuration / WiFi to

set smartCUE connection to target network. Settings depends on the network, however typically it is

necessary to set

▪ IP address

▪ Network name (SSID)

▪ Network type: Infrastructure (important step)

▪ Security type

▪ Security key