Owner’s manual, Troubleshooting – Desa CGN10TLA User Manual

Page 13

Advertising
background image

13

104267

OWNER’S MANUAL

TROUBLESHOOTING

WARNING: Turn off heater

and let cool before servicing.
Only a qualified service person
should service and repair
heater.

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at ODS/pilot

When ignitor button is pressed, there is
spark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out when
control knob is released

CAUTION: Never use a wire,

needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.

POSSIBLE CAUSE

1. Ignitor cable pinched or wet

2. Ignitor electrode not connected to igni-

tor cable

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Ignitor electrode broken
6. Bad piezo ignitor
7. Ignitor electrode positioned wrong

1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5. ODS/pilot is clogged

6. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Safety interlock system has been triggered

4. Equipment shutoff valve not fully open
5. Thermocouple connection loose at con-

trol valve

6. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot

7. Thermocouple damaged
8. Control valve damaged

REMEDY

1. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

2. Reconnect ignitor cable

3. Tighten nut holding piezo ignitor to

heater cabinet. Nut is located inside
heater cabinet at top

4. Replace ignitor cable
5. Replace ignitor
6. Replace piezo ignitor
7. Replace ignitor

1. Turn on gas supply or open equipment

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

5. Clean ODS/pilot (see Cleaning and

Maintenance, page 12) or replace ODS/
pilot assembly

6. Replace gas regulator

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Wait one minute for safety interlock sys-

tem to reset. Repeat ignition operation

4. Fully open equipment shutoff valve
5. Hand tighten until snug, then tighten 1/4

turn more

6. A) Contact local natural gas company

B) Clean ODS/pilot (see Cleaning and
Maintenance
, page 12) or replace ODS/
pilot assembly

7. Replace thermocouple
8. Replace control valve

Continued

Note:

For additional help, visit DESA

International’s technical service web site
at

www.desatech.com

.

Note:

All troubleshooting items are listed in

order of operation.

www.desatech.com

Advertising
This manual is related to the following products: