Vent-free natural gas heater cgn10ta and cgn10tla, Troubleshooting – Desa CGN10TLA User Manual

Page 14

Advertising
background image

14

104267

VENT-FREE NATURAL GAS HEATER

CGN10TA and CGN10TLA

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

Burner does not light after ODS/pilot is lit

Delayed ignition of burner

Burner backfiring during combustion

Yellow flame during burner combustion

Slight smoke or odor during initial operation

Heater produces a whistling noise when
burner is lit

White powder residue forming within burner
box or on adjacent walls or furniture

REMEDY

1. Clean burner orifice (see Cleaning and

Maintenance, page 12) or replace burner
orifice

2. Replace burner orifice
3. Contact local natural gas company

1. Contact local natural gas company
2. Clean burner orifice (see Cleaning and

Maintenance, page 12) or replace burner
orifice

1. Clean burner orifice (see Cleaning and

Maintenance, page 12) or replace burner
orifice

2. Contact local natural gas company
3. Replace burner
4. Replace gas regulator

1. Check burner for dirt and debris. If

found, clean burner (see Cleaning and
Maintenance
, page 12)

2. Contact local natural gas company
3. Replace gas regulator

1. Problem will stop after a few hours of

operation

1. Turn control knob to LO position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas checked by local natural
gas company

3. Observe minimum installation clear-

ances (see Figure 4, page 7)

4. Clean burner (see Cleaning and Mainte-

nance, page 12) or replace burner orifice

1. Turn heater off when using furniture

polish, wax, carpet cleaners, or similar
products

POSSIBLE CAUSE

1. Burner orifice is clogged

2. Burner orifice diameter is too small
3. Inlet gas pressure is too low

1. Manifold pressure is too low
2. Burner orifice is clogged

1. Burner orifice is clogged or damaged

2. Inlet gas pressure is too low
3. Burner damaged
4. Gas regulator defective

1. Not enough air

2. Inlet gas pressure is too low
3. Gas regulator defective

1. Residues from manufacturing processes

1. Turning control knob to HI position

when burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

1. When heated, vapors from furniture pol-

ish, wax, carpet cleaners, or similar prod-
ucts

www.desatech.com

Advertising
This manual is related to the following products: