Planning the Installation

Preparing for Installation

Duct Work Equivalent Lengths

eQuivAlent lengths

piece

subtract

piece

subtract

8” 90° elbow

7 feet

10” 90° elbow

5 feet

8” 45° elbow

3 feet

10” 45° elbow

2 feet

3¼” X 10”

to round 90°

transition

25 feet

3¼” X 10” to

8”/10” round

transition

4 feet

Roof cap

*

Wall cap with

damper

*

* The equivalent lengths of roof and wall caps vary with

model and configuration. For equivalent length, contact the

manufacturer or a qualified HVAC specialist.

Duct Work Design Tips

Wherever possible, reduce the number of transitions

and turns to as few sharp angles as possible. Two

staggered 45° angles are better than one 90°.

Keep turns as far away from the hood exhaust as pos-

sible, and as much space between bends as possible.
For best performance, use round duct instead of rect-

angular, especially when elbows are required.
If multiple elbows are used, try to keep a minimum of

24” straight duct between them.
Avoid “S” or “back to back” use of adjacent elbows.

In regions where the weather gets extremely cold, use

thermal breaks, such as a short section of non-metallic

duct, to avoid indoor heat loss. Locate the break as

close as possible to the outside pass through point.
Do not use flexible metal duct.

Do not

use duct work that is smaller in cross-sectional

area than the recommended types above.

Verify the Package Contents

Unpack the parts box and verify that all parts have been

included according to the parts list on page 5. If any item

is missing or damaged, please contact the dealer immedi-

ately. Do not install a damaged or incomplete appliance.
Make sure you have everything necessary for proper instal-

lation before proceeding.

Mounting Location Preparation

wArning

The electrical service to the range hood should be

installed only by a licensed electrician.
Observe all governing codes and ordinances during

site preparation and installation. Contact your local

building department for further information.
Failure to properly anchor the hood to the wall may

result in personal injury due to the unit falling off the

wall.
To avoid an electric shock hazard and property dam-

age, locate electric wires and water pipes and avoid

drilling or cutting in the vicinity.
Use the temporary mounting brackets only to hold

the hood in place until permanent anchoring is

installed.

Temporary mounting brackets, and the

screws and anchors to hold them in place

during installation are provided with the

hood. Two anchors and screws are used

per bracket.
Determine the number, size and type of

anchors required to attach the hood permanently to the

wall and/or the cabinets based on the type of installa-

tion and the weight chart on page 3.
Make sure the mounting surface is properly reinforced

to handle the full weight

of the hood. If mounting

the unit to a drywall or

plastered surface, install

a reinforced mounting

block between the studs

behind all hood mounting

locations. You may attach

screws directly to the

studs and cabinets if they

line up with the mounting

holes in the back and top

of the hood. If mount-

ing the hood to brick or

masonry, select anchors

capable of holding the full

weight of the hood.