Figure 40 - Control Knob In The OFF

Position

Ignitor
Button

Control
Knob

6. With control knob pressed in, press and

release ignitor button. This will light pilot.

The pilot is attached to the front burner. If

needed, keep pressing ignitor button until

pilot lights.

Note:

If pilot does not stay lit, refer to

Troubleshooting, page 30. Also, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

Note:

If pilot goes out, repeat steps 3

through 7. This fireplace has a safety inter-

lock system. Wait one (1) minute for system

to reset before lighting pilot again.

8. Turn control knob counterclockwise

to desired heating level. The burner should

light. Set control knob to any heat level

between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

OPERATING FIREPLACE

Continued

Figure 42 -Propane/LP Gas Pilot

Thermocouple

Ignitor
Electrode

Pilot Burner

Figure 41 - Natural Gas Pilot

Thermocouple

Ignitor
Electrode

Pilot Burner

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance (if

applicable) if service is to be performed.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat used on this fireplace senses the

room temperature. At times the room may exceed

the set temperature. If so, the burner will shut off.

The burner will cycle back on when room tem-

perature drops below the set temperature.

The control knob can be set to any heat level

between HI and LO.
Note:

The thermostat sensing bulb measures

the air near the fireplace cabinet. This may

not always agree with room temperature (de-

pending on housing construction, installation

location, room size, open air temperatures,

etc.). Frequent use of your fireplace will let you

determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions

, vpage 22.

2. With control knob pressed in, strike match.

Hold match to pilot until pilot lights.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 8 under

Lighting Instructions

, column 1.

OPERATING

BLOWER

This blower has three settings: ON, OFF, and

AUTO. In the ON position, the blower will oper-

ate constantly. In the OFF position, the blower

will not operate. In the AUTO position, the

blower will start when the thermostat senses a

sufficient increase in firebox temperature.
Note:

Your fireplace and thermostat blower

will not turn on and off at the same time. The

fireplace may run for several minutes before the

blower turns on. After the heater modulates to

the pilot position, the blower will continue to

run. The blower will shut off after the firebox

temperature decreases.