Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

two inches from where the pilot flame comes out

of the pilot assembly (see Figures 56 or 57 depend-

ing on model). With the unit off, lightly blow air

through the air inlet hole. You may blow through a

drinking straw if compressed air is not available.

CLEANING AND

MAINTENANCE

Continued

Figure 56 - Pilot Inlet Air Hole

(Propane/LP Gas)

Pilot Assembly

Pilot Air Inlet Hole

Pilot Assembly

Pilot Air
Inlet Hole

Figure 57 - Pilot Inlet Air Hole

(Natural Gas)

WIRING DIAGRAM

(Remote-Ready Models Only)

Switch

Black

Auto

Of

f

On

Red

Red

White

Thermopile

Gas Control

TPTH

TH

TPTH

TP

LOG SET

• If you remove one-piece log set for cleaning,

refer to page 21, for placement instructions.

• Replace log set if broken or chipped (dime-sized

or larger).

CABINET

Air Passageways
• Use a vacuum cleaner or pressurized air to

clean.

Exterior
• Use a soft cloth dampened with a mild soap

and water mixture. Wipe the cabinet to re-

move dust.