Operating fireplace – Desa CDCFTP User Manual

Page 24

Advertising
background image

www.desatech.com

111244-01D

24

OPERATING FIREPLACE

Continued

Note:

It is safe to operate fireplace with blower

turned off. However, the blower helps distribute

heated air from the fireplace.

Figure 43 - AUTO/OFF/ON Blower Switch

AUTO/OFF/ON Switch

REMOTE-READY MODELS

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighborʼs phone. Follow the gas

supplierʼs instructions.

• If you cannot reach your gas supplier, call

the fire department.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the

knob will not push in or turn by hand, donʼt

try to repair it, call a qualified service tech-

nician or gas supplier. Force or attempted

repair may result in a fire or explosion.

D. Do not use this appliance if any part has been

under water. Immediately call a qualified ser-

vice technician to inspect the appliance and to

replace any part of the control system and any

gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate

this fireplace with the screen in

place. Make sure fireplace screen is

installed before running fireplace.

NOTICE: During initial opera-

tion of new fireplace, burning

logs will give off a paper-burn-

ing smell. Open window to vent

smell. Operate fireplace on HI

position to burn off odor. This

will only last a few hours.

WARNING: Burner will come

on automatically within one min-

ute when control valve is in the ON

position after the pilot is lit.

1. STOP! Read the safety information starting

in column 1.

2. Make sure equipment shutoff valve is fully

open.

3. Press in and turn control knob clockwise

to the OFF position (see Figure 44).

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information, column 1. If you donʼt

smell gas, go to the next step.

5. Press in and turn control knob counter-

clockwise

to the PILOT position.

Press in control knob for five (5) seconds

(see Figure 44).

Note:

You may be running this fireplace for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

Figure 44 - Control Knob and Ignitor

Button Location (Shown as Supplied

- No Control Options)

HI

LO

IN

OUT

Piezo
Ignitor
Button

Control
Knob

Flame
Adjustment
Knob

Advertising
This manual is related to the following products: