Installation

L

ΩGIC™ 1X36 User Manual Rev. 08

7
























Do not use the
splitter as a
coupler.














LΩGIC™ 1X36 Product Linking

Use this method when connecting a set of one or more

LΩGIC™ 1X36 products to the same

DMX cable. This is the simplest method to connect multiple products to the same DMX
controller.

1. Connect the RJ-45 plug of the DMX to RJ-45 adapter to the “DMX In” RJ-45 jack on

the first

LΩGIC™ 1X36 product.

2. Connect the XLR male connector of the DMX to RJ-45 adapter directly to the “DMX

Out” (female) connector on the DMX controller or to the DMX cable coming from the
DMX controller.

3. Connect one of the RJ-45 plugs of the signal patch cable to the “DMX Out” RJ-45 jack

on the first

LΩGIC™ 1X36 product.

4. Connect the other RJ-45 plug of the signal patch cable to the “DMX In” RJ-45 jack on

the second

LΩGIC™ 1X36 product.

5. Continue linking the

LΩGIC™ 1X36 products using more signal patch cables, as

shown in the diagram below.

ILUMINARC recommends using a signal terminator after the last

LΩGIC™ 1X36 product.

The easiest way to assemble a signal terminator is by soldering or crimping a 120 ohms resistor
between the terminals corresponding to DATA + and DATA – on a RJ-45 jack. Another
method consists in soldering the 120 ohms resistor to a short cable coming out of a RJ-45 plug.
Once assembled, connect the terminator to the “DMX Out” connector of the last

LΩGIC™

1X36 product.

RJ-45 to DMX adapter

LED patch cable

Signal patch cable

LED patch cable

LED patch cable

Terminator or RJ-45 to DMX adapter

Signal patch cable

Optional splitter