Installation, Mounting, Orientation – ILUMINARC Colorist™ Line 12Qa User Manual

Page 10: Procedure

Advertising
background image

Installation

6

Colorist™ Line 12Qa User Manual Rev. 2

3. Installation














Make sure to mount
this product away
from any flammable

material as indicated in the

Safety Notes

.



Not for permanent
outdoor installation
in locations with

extreme environmental
conditions.





Product aperture
must not hang
between 171° and

189° on the vertical axis in
outdoor environments.

Mounting

Before mounting this product, read and follow the safety recommendations indicated in the

Safety Notes

.

Orientation

Always mount this product in a safe position, making sure there is adequate room for ventilation,
configuration, and maintenance.

Installation

ILUMINARC® recommends following the general guidelines below when mounting the
Colorist™ Line 12Qa.

· When selecting an installation location, consider ease of access to the product for

operation, programming adjustments and routine maintenance.

· Product aperture must not hang between 171° and 189° on the vertical axis in outdoor

environments.

· Not for permanent outdoor installation in locations with extreme environmental

conditions.

· Make sure the product’s mounting location can support its weight. See the

Technical

Specifications

for the weight requirement(s) of this product.

Procedure

The Colorist™ Line 12Qa comes with two adjustable feet that double as hanging brackets to
which you can attach clamps using the M12 holes in the bottom. These brackets also serve as
floor stands or wall-mount supports. You must supply your own clamps and make sure the
clamps are capable of supporting the weight of this product. You must use two mounting points
per product. Product aperture must not hang between 171° and 189° on the vertical axis in
outdoor environments.
























90°

to

170°

Mounting Clamp

190°

to

255°

171°

to

189°

Safety
Cable