Dmx linking, Dmx modes, Signal wiring – ILUMINARC Ilumipod™ 18g2 IP User Manual

Page 12: Protocol connectivity, Installation

Advertising
background image

Installation

8

Ilumipod 18g2 IP Optic WW User Manual Rev. 3

The Ilumipod
18g2 IP Optic
WW must be
linked using DMX

cable in a daisy chain
(serial) fashion. To
comply with the EIA-485
standard, no more than
32 products should be
connected on one daisy
chain without using a
DMX optically isolated
splitter. Doing otherwise
may result in deterioration
of the digital DMX signal.

USITT
recommends
limiting the total

length of the DMX cable
(from the first
product/controller to the
last product) to 300–455
m (985–1,500 ft).

Disconnect the
product from the
AC power before

opening it.

The signal cable
must match or
exceed the

electrical characteristics
of the Belden® 9841
cable for EIA RS-485
applications. You may
also use CAT5, 5e, or
CAT6 LAN cable.

DMX Linking

You may link the Ilumipod 18g2 IP Optic WW to a DMX controller using a standard DMX
serial connection. If using other DMX products compatible with the Ilumipod 18g2 IP Optic
WW, you can control each individually with a single DMX controller.
If you are not familiar with the DMX standard, or if you need information about the DMX
cables needed to link the Ilumipod 18g2 IP Optic WW to a DMX controller, you may
download the “DMX Primer” from the ILUMINARC® website at

http://www.iluminarc.com/reports/dmx-primer

.

DMX Modes

The Ilumipod 18g2 IP Optic WW uses the standard DMX data connection for its DMX
personality, SOLID. Refer to the

Introduction

chapter for a brief description of this mode.

Refer to the

Operation

chapter to learn how to configure the Ilumipod 18g2 IP Optic WW to

work in this mode. The

DMX Values

section provides detailed information regarding the

DMX modes.

DMX Mode

DMX Address

SOLID

512

Signal Wiring

To provide signal for the Ilumipod 18g2 IP Optic WW, you can connect the bare-ended,
IP67-rated signal cable from the product to two IP67-rated signal connectors (DMX In/DMX
Out) or use an IP67-rated junction box. In this case, make sure to use

IP67-rated conduit.

Protocol Connectivity

The Ilumipod 18g2 IP Optic WW uses the USITT DMX 512 protocol. The procedure below
illustrates the recommended connection method.


























Advertising