Beam angle adjustment, Installation – ILUMINARC Ilumipod™ Inground Tri-12 IP User Manual

Page 11

Advertising
background image

Installation

Ilumipod Inground Tri-12 IP Optic WW User Manual Rev. 3

7







Make sure to
disconnect the
power to the

product before opening it.









Be careful when
opening and
closing the

product’s housing as it
may compromise the
product’s IP67 rating.




Beam Angle Adjustment

The Ilumipod Inground IP products have two LED modules each. You can adjust the
angle of each of these modules to spread or narrow the product’s beam. To do so,
follow these steps:

1. Loosen the Allen bolts on the stainless steel collar by turning them CCW, not

more than a turn or two, enough to release the aluminum latch from its
“locked” position.

2. Lift the product from the installation sleeve, making sure not to stretch the

power and signal cables.

3. Loosen 4 of the 6 nuts that hold the collar to the housing, leaving untouched

any two adjacent nuts.

4. Wait a few seconds for the seal to expand. This lowers the possibility of

damaging the seal.

5. Complete the removal of the two remaining nuts.

6. Remove the stainless steel collar.

7. Carefully, lift and remove the protective glass and seal attached to it, making

sure not to reverse the glass.

8. Using only your hands, push on the sides of each module to adjust its angle, as

shown in the figure below.

9. Replace the glass and seal.

10. Replace the stainless steel collar, making sure to align it with the Allen bolts

and that the glass surface is flush with the collar.

11. Replace all 6 nuts and adjust them manually until they touch the housing.

12. Tighten the nuts uniformly by alternating between opposite nuts.

13. Reattach the product to the installation sleeve by turning the Allen bolts CCW.

You should only need a turn or two to have the stainless steel collar firmly
attached.





Advertising