C8817
3/8
installation
CAN ADDR
Set the CAN ADDR rotary encoder to an address, which is not in
use by another module of a C8000 frame (for details regarding
CAN addressing, see C8000 system manual).
SW3A
Towards the bottom enables the CAN “+16” address schema to
handle up to 32 modules. If "+16" is turned on, addresses set by
the rotary encoder counting from 0x10 to 0x1F.
SW3B
Not used, must be set towards the bottom.
INIT
Pressing the INIT button during power up will initialize the module
parameters to factory default values.