4. LOCATION OF PARTS AND CONTROLS

4.3

SWITCHES AND
JUMPERS FOR
CONFIGURATION

Some basic settings are to select by switches on the rear panel
or by switches and jumpers at the internal circuit boards of the
unit. These settings can occur general changes for operation
and should made by qualified engineering staff only.

Rear panel

Following switches in the REMOTE- field at rear panel are used
for configuration of the unit.


SDI Bypass switches SDI bypass on/off (see also 3.10)

(only for SDI version!)



LOCAL

Setting of FRONT PANEL operation mode


ENABLE

Unit can be controlled by front panel and by

serial remote interface.


DISABLE Unit can be controlled only by using serial remote

interface. Front panel is locked.

Note: DISABLE is only activated if serial remote

control is connected!



ADDR

Selection of the device address for serial

remote, 16 device addresses selectable

Note: Within a line of remote controlled units every

device needs a different address! The selected

address is valid after next power-on reset of the unit.



Internal


To set any internal jumper or switches it is necessary to open
the unit.

PLEASE DO NOT MAKE ANY ALTERATIONS WITH THE
MAINS STILL CONNECTED TO THE UNIT!

Loosen the screws on the top cover and remove. Then you can
see all jumper and switches as shown in the drawing below.
After setting of jumper or switches reassemble the unit in
opposite order.





Operation manual b45, chapter 4 -location of parts and controls- page 4-3