Appendix f: power consumption – NEXCOM VTC 1000 User Manual
Page 70
Advertising

Copyright © 2011 NEXCOM International Co., Ltd. All rights reserved
57
VTC 1000 User Manual
Appendix F: Power Consumption
Appendix F: Power Consumption
Test Equipment/Tool
DUT#1 : VTC1000 with SSD (Apacer commercial serial ATA flash Drive 16G)
DUT#2 : VTC1000 with SSD (Apacer commercial serial ATA flash Drive 16G) +3.5G MODULE(MC8790V PCI EXPRESS MINI CARD )
Windows XP
Burn-in Software: Version 5.0
Test Condition
Room temperature
Power supply graduation: 12V 5A
Test Procedure:
1. Start of all function at DUT and measure power consumption.
2. Get system into suspend mode and measure power consumption.
Unit
Idle Mode
100% Burn-in Mode
S3
S4
S5
DUT#1
1.03A
1.18A
90mA
10mA
10mA
DUT#2
1.13A
1.24A
140mA
50mA
50mA