(1) Cooling Mode
* When the room temperature is higher than 22˚C or

equal to 22˚C

1

Fan Speed: high speed (Fixed)

2

Air discharge direction: The control is available.

3

Set temperature: 18°C (Fixed)

(1) Heating Mode
* When the room temperature is lower than 22˚C

1

Fan Speed: high speed (Fixed)

2

Air discharge direction: The control is available.

3

Set temperature: 32°C (Fixed)

Dehumidification Mode

Air Discharge Direction

Quick Mode(Powerful Cooling & Heating)

1

DT+1˚C

<

RT

Outdoor Fan, Compressor : ON
Indoor Fan : Low speed

2

DT-1˚C RT DT+1˚C
Outdoor Fan, Compressor : 3 min/ON, 5 min/OFF
Indoor Fan : Low speed

3

DT-1˚C > RT
Outdoor Fan, Compressor : OFF
Indoor Fan : Low speed

<

<

1. Press fan direction button to select fan direction

• Press desired fan direction button, "UP • DOWN" or "LEFT • RIGHT" control louver moves, press

again to stop

FAN DIR.

FAN DIR.

Self-Diagnostic Function

The control will contain diagnostic test to verify the integrity of the system.

(1) Error Code Display : RT (Room Temperature) LED

ERROR CODE

DISPLAY

ERROR CONTENTS

1

“E2”

Indoor unit sensor open or short

2

“E2”

Outdoor unit sensor open or short

3

“ E3 ”

Compressor, Electrical parts of

comp. Gas leak