7. TROUBLE SHOOTING

Outdoor unit does

not run?(note. 1)

Does

the compressor run

normally?

Indoor unit does

not run(note 1)

Check the failure

code according to

the self diagnostic

(note 2)

Is the unit

display

mormal?

check the failure

code according to

the self-diagonostic

(note 2)

Normal

check the

connecting

point of

magnetic
contactor

YES

YES

YES

YES

NO

NO

YES

Trouble

Is the power

applied to the

unit

Is the

power normal?

check the voltage between

L & N of terminal

block

press the power ON/OFF

button on remote controller

Does the

beeper beep two

times?

Is the display

all off?

• Check the connector on display

PCB connected to control PCB

• Check the display PCB itself

Check power supply mains

or interconnection wires

Check the wiring of indoor

Does

control PCB

status LED repeat one

second "on and

off"?

• control PCB fault

• Micom or reset

IC fault

• Check the remote signal receiver

• Check the connection between signal

receiver and control PCB

YES

NO

NO

NO

NO

YES

YES

YES

YES

YES

NO

NO

NO

Is the

unit display

normal?