Paxton Superchargers Dodge Viper User Manual

Page 28

Advertising
background image

9-4

P/N: 4809643
©2004 Paxton Automotive
All Rights Reserved, Intl. Copr. Secured
12APR04 v1.1 01-03Viper(4809643v1.1)

9.

Connect using the supplied hose

mender and tighten a plastic clamp on

each connection. (See Fig. 9-o for

plumbing schematic.)

10. Trim the hood release handle to clear

the water cooler as shown in Fig. 9-j. If

necessary, drill 1/8" holes in a new

location to remount the handle so that

its function is not impaired.

Fig. 9-j

Fig. 9-l

Fig. 9-k

E.

Surge Tank Installation
1.

Using thread sealant, install the sup-

plied 1/2" NPT to 3/4" hose barb

straight fittings into the front and side

of the surge tank. (See Fig. 9-k.)

2.

Drill a 5/16" hole 3/4" in front of the

hole that already exists in the driver’s

side shock tower. Install the supplied

1/4" screws through a washer, the

shock tower, a supplied .3" spacer and

into the surge tank.

3.

Install a 90° hose onto the fitting on top

of the reservoir and secure with a

clamp. (See Fig. 9-l.)

4.

Connect the surge tank fitting (pointed

towards the front of the vehicle) to the

hose elbow installed in the top of the

reservoir using a hose mender and a

section of the supplied hose. Install and

tighten a clamp on each connection.

5.

Trim and connect a section of the sup-

plied hose from the 90° hose installed

on the CAC end tank to the fitting on

the surge tank that is pointed toward the

engine. Select the smoothest routing

that will keep the hose away from mov-

ing parts and secure the CAC end with

a clamp. Leave the surge tank end loose

until after the system is bled.

6.

Plug the open fitting in the surge tank,

remove the cap and fill the system with

25%/75% coolant/water mix. Fill the

system slowly until it refuses to take

more coolant or coolant comes out ot

the open hose.

7.

Uncap the surge tank fitting, connect

the open hose to it, and tighten with

clamp.

8.

Loosely install the plastic cap.

TRIM EXCESS HANDLE UP TO THIS POINT

Fig. 9-i

8.

Route a 3/4" hose from the remaining

fitting on the water cooler through the

two holes drilled on the passenger’s

side, and connect to the 90° fitting

installed on the CAC. (See Fig. 9-i.)

Fig. 9-h

***NOTE***

Trial fit the surge tank by installing the rear mounting

screw through the existing hole in the driver side

shock tower. Close the hood, verify that it clears the

surge tank cap and proceed with step 2. If there is

interference, lower the surge tank and drill out the

mounting holes accordingly.

Advertising