HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-15

Installing the New Temperature Probe:

1. Feed the probe wire through the probe nipple from the top side of the frypot.

2. Loosely install the bladder nut.

3. Mount the probe into the mounting hardware. Carefully bend the two tabs back into alignment to

retain probe.


4. Tighten the bladder nut.

5. Install the insulation and plug.


1.7.3 Replacing the High-limit Thermostat

1. Turn fryer off and drain oil from the frypot. Allow the frypot to cool completely before

proceeding.

2. Perform steps 1-4 in Section 1.7.1, Replacing the Controller.

3. Remove fryer door for easier access to the temperature probe. First, remove top hinge from

bracket. Then, lift door off bottom hinge pin.

4. Remove two screws securing the high-limit

mounting-bracket. Do not disconnect wires from
high-limit at this time.











5. Loosen and completely unscrew the compression

nut, then the pass-through nut on the frypot bottom.
Proceed to the next step before removing high-limit
from frypot.








Remove screws (arrows) securing high-limit to
fryer.

Compression nut unscrewed. Unscrew
the pass-through nut (arrow).

Advertising
This manual is related to the following products: