CHAPTER 1: SERVICE PROCEDURES

1-36

1.9 Troubleshooting

Guides


The following troubleshooting guides are intended to assist service technicians in quickly isolating
the probable causes of equipment malfunctions by following a logical, step-by-step process.

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Burner will not ignite.

Light in ON/OFF switch

is not illuminated.

A. ON/OFF switch is off.

A. Turn ON/OFF switch on.

ON/OFF switch is on,

but the switch light is not

illuminated.

A. No voltage at switch.

A. Ensure line voltage is present at the

switch.

ON/OFF switch is on and

the switch light is

illuminated, but there is

no output to gas valve.

A. Drain microswitch circuit (filter-

equipped units) is open.

A. Ensure drain valve is fully closed and

microswitch is functioning. Replace
microswitch if defective.

B. Voltage is present at ON/OFF switch,

but continuity of the switch in ON
position is not "0.”

B. ON/OFF switch is defective. Replace

switch with a known working switch.

C. Continuity of thermostat is not "0" (oil

temperature is at least 15°F below
electronic thermostat setting).

C. Thermostat(s) is/are defective.

Replace defective thermostat with a
known working thermostat.

D. Gas valve is suspect.

D. Go to "No burner flame" section.

No burner flame.

C. Gas valve is known to be good, but

there is not 24 VAC (120VAC on
systems so equipped) at the gas valve
terminals.

D. Inspect electronic sensor (while still in

frypot) for damage. Replace if bent,
dented, or cracked. Inspect leads for
fraying, burning, breaks, and/or kinks.
If found, remove and replace
thermostat(s). Remove leads from
terminal block, allow oil to cool 15°F
(8°C) below thermostat setting, and
check continuity. If continuity is not
"0,” then thermostat has failed.
Replace thermostat(s).

Fluctuating or erratic

lighting of burner flame.

A. Incoming gas supply pressures are not

within range [Natural- 6-14" W.C.
(1.49-3.49 kPa); Propane- 11-14"
W.C. (2.74-3.49 kPa)]

A. Inspect gas supply to fryer. Repair

and/or replace faulty components
(defective supply shut-off valves,
incorrect piping size, etc.)

B. Air in gas supply lines (new

installation).

B. Allow unit to cycle on and off for

approximately 30 minutes to force air
from gas manifold and lines.

Electronic/operating

thermostat will not adjust

to correct temperature.

A. Electronic/operating thermostat is out

of calibration.

A. Calibrate electronic/operating

thermostat. Replace if calibration is
not possible.