Summary, Operational features, Description – Toyotomi TAD-30K User Manual

Page 4: Safety tips

Advertising
background image

1

SUMMARY

The idea behind the unit is to provide a localized supply of cool air.

The unit will greatly enhance your personal comfort whether at
a work station or even in your favorite chair.

Four (4) casters enable you to move the unit easily from room
to room. It cools and dries the air at the same time so that you
can stay comfortable even when it's humid or rainy outside.
Also your furnishings and fabrics are kept in good condition
when it's used as dehumidifier.

Conventional air conditioners use large quantities of energy to
cool an entire room, including walls and furniture. This unit
creates a zone of cool and dry air only where it is needed. It
does not waste energy cooling the surroundings.

It's easy to operate. The built-in timer allows from 1 to 12 hours
of operation, which will automatically turn the unit on and off.
This is especially convenient at bedtime.

Venting is not required. However, if the unit is to be used exclu-
sively in one space, the cooling efficiency will be enhanced by
using the venting kit accessory, which is included with the uit.

OPERATIONAL FEATURES

1.

COOLING OPERATION:
Normally, cool air is directed out the front louvers by the
circulation fan which has three (3) stages of fan speed.

2.

AUTOMATIC OPERATION:
Once the desired function has been set, it is memorized as
long as it remains connected to the wall outlet. In the event
of a power failure, the desired function must be re-entered
when power is restored.

3.

THERMO CONTROL
The compressor will automatically shift to ON or OFF to
maintain the desired temperature.

4.

TIMER OPERATION:
The unit will turn on and off after the designated period of
time (1, 2, 3, ...12 hours).

5.

AUTOMATIC SHUT-OFF MECHANISM WHEN THE
DRAIN TANK IS FULL:
When the drain tank is full, the unit will be automatically
shut off. The warning lamp will light. It is always required
to press the power button twice to resume operation after
the condensed water is removed from the tank.

6.

AIR FILTER:
A pre-filter protects the unit from dust.

1. DESCRIPTION

Fig. A

FRONT

A1

Air outlet

A2

Vertical louver

A3

Front panel

A4

Operation panel

A5

Carrying handle

A6

Horizontal louver

A7

Caster

Fig. B

REAR

B1

Air intake (Evaporator)

B2

Exhaust outlet

B3

Air intake (Condenser)

B4

Power supply cord

B5

Power plug

B6

Drain water outlet

B7

Air intake grille (Pre-filter)

Fig. C

OPERATION PANEL

C1

Power button

C2

Mode button

C3

Fan speed button

C4

Timer button

C5

Adjust buttons

C6

Warning lamp (Tank full)

C7

Cool mode lamp (green)

C8

Dry mode lamp (orange)

C9

Fan mode lamp (yellow)

C10 Room temp lamp
C11 Set temp lamp

C12 Timer set lamp
C13 Digital indicator
C14 Signal receptor
C15 C/F toggle button (Remote control)

Fig. I

EXHAUST DUCT SET

I1

Exhaust duct hose adapter nozzle (2 pcs.)

I2

Exhaust duct hose

Fig. J

WINDOW PANEL KIT

J1

Window panel

J2

Window panel extension

J3

Exhaust duct hose grille

J4

Cover

J5

Screws

2. SAFETY TIPS

IMPORTANT
¡

Read instructions carefully before operation.

¡

The unit should be operated when the room temperature is
between 64˚F (18˚C) to 95˚F (35˚C). If the room temperature
is below 64˚F (18˚C), ice may form on the coils. If the room
temperature is above 95˚F (35˚C), the compressor will auto-
matically shut off to protect itself.

¡

ALWAYS, wait 3 min. to restart after turning unit off.

WARNING

¡

NEVER expose infants, handicapped persons, or senior
persons directly to the airflow. Adjust the airflow direction.

¡

Keep children away from unit. Children are particularly li-
able to this danger. The inside fan is running at high
speed. Covering them may deteriorate air conditioner per-
formance or cause it to become inoperative.

¡

NEVER insert objects of any kind into the air intake or air
outlet.

¡

DO NOT unplug if your hands are wet. An electrical shock
may occur.

¡

DO NOT operate in a wet location.

¡

ALWAYS plug into 115 V, 60 Hz, single phase electrical out-
let.

¡

Be sure the power plug fits the receptacle securely.

¡

DO NOT run power cord under carpets, rugs, or floor mats
of any kind.

¡

DO NOT attempt to shorten or alter power cord in any way.

¡

DO NOT apply any excessive force or pressure to the pow-
er supply cord.

¡

Make sure that the plug is free of dust.

¡

DO NOT use an extension cord.

¡

DO NOT turn on and off by inserting or removing the pow-
er plug which may cause electric shock or fire.

¡

If there is a fear of lightning, stop the unit and disconnect
the power supply cord.

¡

DO NOT touch the evaporator, condenser and pipes.

¡

DO NOT operate with filter removed.

CAUTION

¡

Keep unit more than 20 in. (50 cm) away from any objects
or wall. (Fig. D)

¡

If the unit is operated in COOL mode in an area of very
high moisture, the top plate and the rear plate may get
covered with a mist. Wipe off any mist before it has a
chance to get on the floor or rug.

¡

Remove drain water before moving unit.

¡

To minimize corrosion, DO NOT use in damp, salty air
area.

¡

DO NOT operate in direct sunlight.

¡

DO NOT use for such particular purpose as preservation of
foodstuff, animals, plants, precision appliances, arts and
medicine.

¡

DO NOT place an animal, plants or combustion equipment
in a place which is subjected to the direct air flow of the
unit.

¡

DO NOT ride or place the objects on the unit.

¡

DO NOT turn the unit on its side or upside down.

ENGLISH

TAD-30K (GB/ES/FR) 10.3.8 2:44 PM ページ 1

Advertising