VC-300DLP Antenna Tuner

Owner's Manual

8

METER CALIBRATION

METER CALIBRATION PROCEDURE

Connect transceiver to TRANSMITTER IN connector.

Connect external 50

load to COAX 2 connector.

Set the OUTPUT SELECT switch to the COAX 2 DIRECT position.

Set the RANGE button to 300 W and the PEAK/AVG button to AVG.

Apply 100 W of RF at 14.0 MHz.

Adjust R1 (see Figure 1) so that 100 W of FORWARD power is read on the meter.

Reduce the RF power to 10 W and set the RANGE to10 W.

Adjust R2 so that 10 W of FORWARD power is read on the meter.

Reverse the transceiver and load connectors on the rear panel.

Set the RANGE to 300 W.

Apply 10 W of RF power and adjust R4 to read 10 W of REFLECTED power.

Set the RANGE to30 W.

Apply 2W of RF power and adjust R3 to read 2 W of REFLECTED power.