Xtramus NuWIN V1.1 User Manual
Page 26
 
 
 
 
21
E-mail: [email protected]
Website: www.
X
tramus.com
XTRAMUS TECHNOLOGIES
®
Data Integrity / 
Sequence 
Checking 
Yes
Source / 
Destination 
MAC Address 
Fixed /Increase /Decrease/Random
Variable fields can be set depending on UI, max length of each field 
of 48-bit 
Source / 
Destination 
IP Address 
Fixed /Increase /Decrease/Random
IP/TCP 
Generation/ 
Analysis 
Hardware
Hardware 
counters 
TX Packet/Byte, RX Packet/Byte, Unicast, Multicast, Broadcast, 
VLAN Packet, Pause Packet, CRC Error, DI Checksum Error, Serial 
Number Error, Alignment Error, Oversize Packet, Undersize Packet, 
Dribble Bit, IP Checksum Error, Trigger 1 ~ Trigger 8, Collision 
TxArpReq, TxArpReply, RxArpReq, RxArpReply, TxICMPReq, 
TxICMPReply, RxICMPReq, RxICMPReply 
VLAN (VLAN ID / 
COS Field) 
Fixed/ Increase/ Decrease/ Random
MPLS(Label, 
COS, TTL Field) 
Fixed/ Increase/ Decrease/ Random (No. of labels no limited)
Flow Control
Yes
Capture Buffer 
Size 
63 MB per port (up to 825k frames)
Capture Mode
Event
Capture Event
DI Error, Serial No. Error, Alightmnet Error, IP Checksum Error, 
Trigger 1~8, Trigger Logic, Any Defined Packet Size 
QoS Testing
Up to 8 Priority Queues
Line 
Performance 
Wire Speed
Please note that the module card can be removed with that slot being powered off in
NuStreams-2000i. Or shut down the chassis before plugging/unplugging any module
cards.