Analog Way OPS200 Programmer's Guide User Manual
Page 22
![background image](/files/771840/content/doc022.png)
22
Group
Name
CmdResp Description
Read
/
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
SET_HTOTAL
ST ST
Input total pixel per line
Rd/Wr0
65535 0
Unit = pixels.
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_PHASE
SS SS
Input Phase
Rd/Wr0
31
16
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_AUTOCAD
Sa Sa
Input autocentering reques
Rd/Wr0
1
0
Auto reset
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_USER_GAIN_R
sr
sr
ADC R channel adjustment
(advanced setting)
Rd/Wr0
255
128
128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12