Analog Way OPS200 Programmer's Guide User Manual

Page 39

Advertising
background image

39

Group

Name

CmdResp Description

Read
/
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

PE_CLOSING_DURATION

cD cD

Layer closing transition duration Rd/Wr0

255

10

Unit = 1/10s

0 = Current
preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4

0 = Background
Frame for output
1
1 = Background
Frame for output
2 in matrix mode
2 = Background
Layer for output 1
3 = Pip 1 Layer
for output1
Background
Layer for output 2
in matrix mode
4 = Pip 2 Layer
for output1
6 = Logo 1
7 = Logo 2
8 = Audio Output
1
9 = Audio Output
2

PRESET
CONTROL

TAKE

TK TK

TAKE, Next preset becomes
Current

Rd/Wr0

1

0

TAKEAVA

TA TA

Available TAKE flag

Rd

0

1

1

TAKEINFO

TI

TI

TAKE information

Rd

0

2

0

0 = 1 shot TAKE
1 = 2 shot TAKE
2 = Sequenced TAKE

TBAR

NT NT

TBAR value

Rd/Wr0

10000 0

Unit = 0,01%

COPY_FROM

Nf

Nf

Source for preset copy

Rd/Wr0

6

0

0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4

COPY_TO

Nt

Nt

Destination for preset copy

Rd/Wr0

6

0

0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4

COPY_CTRL

Nc Nc

Preset copy control

Rd/Wr0

1

0

Auto reset

Advertising